Skip to content

Construction documents

Activity library

Choose a work package or filter by discipline and project phase to find the records you need to plan, inspect and hand over the work.

170 activities matching “test”

Search the document library
Preliminaries & Enabling WorksActivities: 12
ACT-001

Site Mobilisation and Site Establishment

Project Management · Before Construction

Inspection covers compound plan, emergency access and utility releases.

4 available documentsMSCHKITP
ACT-002

Setting Out and Survey Works

Project Management · Before Construction

Inspection covers coordinates, survey closure and instrument calibration.

4 available documentsMSCHKITP
ACT-003

Site Hoarding and Gates Installation

Project Management · Before Construction

Inspection covers alignment, anchorage, gate swing and pedestrian segregation.

4 available documentsMSCHKITP
ACT-004

Temporary Site Offices and Facilities

Project Management · Before Construction

Inspection covers cabin IDs, bearing, exits and utility checks.

4 available documentsMSCHKITP
ACT-005

Temporary Power and Water Supply

Project Management · Before Construction

Inspection covers circuit IDs, isolation and backflow evidence.

4 available documentsMSCHKITP
ACT-006

Tower Crane Installation, Climbing and Dismantling

Project Management · Before Construction

Inspection covers configuration, tie checks, certificates and restrictions.

4 available documentsWIRMSITP
ACT-007

Passenger/Material Hoist Installation and Dismantling

Project Management · Before Construction

Inspection covers mast configuration, gate interlocks and rated load certificate.

4 available documentsMSCHKITP
ACT-008

Mobile Crane Lifting Operations

Project Management · Before Construction

Inspection covers approved radius, rigging certificates and supervisor release.

4 available documentsMSCHKITP
ACT-009

Scaffolding Erection and Dismantling

Project Management · Before Construction

Inspection covers ties, platforms, access and edge protection.

4 available documentsMSCHKITP
ACT-010

Temporary Works (Propping and Back-Propping)

Project Management · Before Construction

Inspection covers prop grid, retained levels, loads and removal authorisation.

4 available documentsMSCHKITP
ACT-011

Traffic Management and Site Logistics

Project Management · Before Construction

Inspection covers traffic plan, clearance walkdown and route changes.

4 available documentsMSCHKITP
ACT-012

Demobilisation and Site Clearance

Project Management · Before Construction

Inspection covers removal list, waste tickets and returned condition.

4 available documentsMSCHKITP
Earthworks & FoundationsActivities: 16
ACT-013

Site Clearance and Grubbing

Civil · During Construction

Inspection covers clearance boundary, retained assets and disposal tickets.

4 available documentsMSCHKITP
ACT-014

Excavation Works

Civil · During Construction

Inspection covers strata, levels, temporary stability and bearing release.

4 available documentsMSCHKITP
ACT-015

Shoring Works (Sheet Piles / Secant Piles / Contiguous Piles)

Civil · During Construction

Inspection covers toe levels, alignment and trigger/action monitoring.

4 available documentsMSCHKITP
ACT-016

Diaphragm Wall Construction

Civil · During Construction

Inspection covers depth, verticality, support-fluid properties and panel concrete volumes.

4 available documentsMSCHKITP
ACT-017

Dewatering Works

Civil · During Construction

Inspection covers water levels, discharge quality and shutdown release.

4 available documentsMSCHKITP
ACT-018

Bored Piling Works

Civil · During Construction

Inspection covers strata, depth, volume, pile ID and as-built survey.

4 available documentsMSCHKITP
ACT-019

Pile Load Testing (Static / Dynamic)

Civil · During Construction

Inspection covers load/displacement or dynamic trace, timestamps and engineer disposition.

4 available documentsMSCHKITP
ACT-020

Pile Integrity Testing

Civil · During Construction

Inspection covers pile ID, trace repeatability and report; no capacity inference.

5 available documentsTESTMSCHK
ACT-021

Pile Head Cutting and Trimming

Civil · During Construction

Inspection covers cut-off survey, exposed concrete and retained rebar.

4 available documentsMSCHKITP
ACT-022

Blinding Concrete

Civil · During Construction

Inspection covers thickness, level and release for next layer.

4 available documentsMSCHKITP
ACT-023

Below-Grade Waterproofing (Membrane)

Civil · During Construction

Inspection covers product compatibility, seam checks and concealed photographs.

4 available documentsMSCHKITP
ACT-024

Anti-Termite Treatment

Civil · During Construction

Inspection covers batch, coverage, treatment certificates and re-treatment areas.

4 available documentsMSCHKITP
ACT-025

Raft Foundation Construction

Civil · During Construction

Inspection covers cover, embed locations, concrete tests and raft survey.

4 available documentsMSCHKITP
ACT-026

Pile Caps and Grade Beams

Civil · During Construction

Inspection covers pile-to-cap detail, anchorage, cover and survey.

4 available documentsMSCHKITP
ACT-027

Backfilling and Compaction

Civil · During Construction

Inspection covers fill source, lift thickness, moisture, density and rework.

4 available documentsMSCHKITP
ACT-028

Soil Compaction Testing (Field Density Test)

Civil · During Construction

Inspection covers moisture, dry density, relative compaction and retests.

4 available documentsMSCHKITP
Concrete StructureActivities: 22
ACT-029

Formwork for Columns and Walls

Structural · During Construction

Inspection covers dimensions, plumb, cleanout and pre-pour approval.

4 available documentsMSCHKITP
ACT-030

Formwork for Slabs and Beams

Structural · During Construction

Inspection covers camber, levels, support layout and opening protection.

4 available documentsMSCHKITP
ACT-031

Core Wall Jump Form / Climbing Form System

Structural · During Construction

Inspection covers anchor IDs, platform release and cycle configuration.

4 available documentsMSCHKITP
ACT-032

Table Form / Flying Form System

Structural · During Construction

Inspection covers table ID, lifting points and receiving-bay survey.

4 available documentsMSCHKITP
ACT-033

Reinforcement Steel Fixing

Structural · During Construction

Inspection covers bar heat, grade, spacing, laps and cover.

4 available documentsMSCHKITP
ACT-034

Mechanical Couplers (Rebar Splicing)

Structural · During Construction

Inspection covers lot, engagement or torque, sample tests and concealment release.

4 available documentsMSCHKITP
ACT-035

Concrete Pouring (General)

Structural · During Construction

Inspection covers tickets, consistency, temperature, sample IDs and pour card.

4 available documentsWIRMSITP
ACT-036

Mass Concrete Pouring (Raft)

Structural · During Construction

Inspection covers probe IDs, temperature curves, approved limits and deviations.

4 available documentsMSCHKITP
ACT-037

Concrete Pumping Works

Structural · During Construction

Inspection covers line inspection, restraint, approved setup and washout disposal.

4 available documentsMSCHKITP
ACT-038

Hot Weather Concreting

Structural · During Construction

Inspection covers ambient and load temperature, elapsed time and rejection evidence.

4 available documentsMSCHKITP
ACT-039

Concrete Curing

Structural · During Construction

Inspection covers timing, coverage, interruptions and curing release.

4 available documentsMSCHKITP
ACT-040

Construction Joints and Waterstops

Structural · During Construction

Inspection covers location, splice integrity and photos on both faces.

4 available documentsMSCHKITP
ACT-041

Post-Tensioned Slabs

Structural · During Construction

Inspection covers tendon IDs, elongation, jack calibration and closure evidence.

4 available documentsMSCHKITP
ACT-042

Precast Concrete Elements Installation

Structural · During Construction

Inspection covers piece marks, bearing length, restraint and connection evidence.

4 available documentsMSCHKITP
ACT-043

Hollow Core Slab Installation

Structural · During Construction

Inspection covers seat lengths, unit damage and opening restrictions.

4 available documentsMSCHKITP
ACT-044

Concrete Repair Works

Structural · During Construction

Inspection covers depth and extent, materials and verification results.

4 available documentsMSCHKITP
ACT-045

Core Drilling and Coring Tests

Structural · During Construction

Inspection covers scan, orientation, custody, lab results and repair.

4 available documentsMSCHKITP
ACT-046

Embedded Items and Sleeves Installation

Structural · During Construction

Inspection covers coordinates, level, rotation and rebar clearance.

4 available documentsMSCHKITP
ACT-047

Staircase Construction

Structural · During Construction

Inspection covers rise, going, landings and edge protection.

4 available documentsMSCHKITP
ACT-048

Shear Walls and Lift Cores

Structural · During Construction

Inspection covers core verticality, shaft dimensions and embedded brackets.

4 available documentsMSCHKITP
ACT-049

Water Tanks (Concrete) Construction

Structural · During Construction

Inspection covers joint continuity, level observations and leak disposition.

4 available documentsMSCHKITP
ACT-050

Formwork Striking and Removal

Structural · During Construction

Inspection covers strength evidence, time, retained support and condition.

4 available documentsMSCHKITP
Structural Steel & RoofActivities: 7
Masonry & Architectural FinishesActivities: 24
ACT-058

Blockwork (Hollow / Solid / AAC)

Architectural · During Construction

Inspection covers block type, joints, plumb and lintel release.

4 available documentsMSCHKITP
ACT-059

Internal Plastering

Architectural · During Construction

Inspection covers thickness, surface plane, corners and cracks.

4 available documentsMSCHKITP
ACT-060

External Plastering / Rendering

Architectural · During Construction

Inspection covers weather record, mesh, terminations and appearance.

4 available documentsMSCHKITP
ACT-061

Floor Screeding

Architectural · During Construction

Inspection covers levels, moisture and thickness before finishes.

4 available documentsMSCHKITP
ACT-062

Floor Tiling (Ceramic / Porcelain)

Architectural · During Construction

Inspection covers shade, alignment, lippage and falls.

6 available documentsWIRMSRA
ACT-063

Wall Tiling

Architectural · During Construction

Inspection covers plumb, alignment, wet transitions and penetrations.

4 available documentsMSCHKITP
ACT-064

Marble and Granite Installation

Architectural · During Construction

Inspection covers slab marks, colour consistency, joints and support inspection.

4 available documentsMSCHKITP
ACT-065

Wet Area Waterproofing

Architectural · During Construction

Inspection covers coverage, collar detail, upstands and water test.

4 available documentsWIRMSITP
ACT-066

Gypsum Board Partitions

Architectural · During Construction

Inspection covers board layers, screws, head detail and concealed photos.

4 available documentsMSCHKITP
ACT-067

Gypsum Board / Mineral Fibre False Ceiling

Architectural · During Construction

Inspection covers plenum release, ceiling level, support spacing and access.

5 available documentsCLOSEOUTMSCHK
ACT-068

Internal Painting

Architectural · During Construction

Inspection covers batch, colour, application condition and defects.

4 available documentsMSCHKITP
ACT-069

External Painting

Architectural · During Construction

Inspection covers weather, coverage and finish consistency.

4 available documentsMSCHKITP
ACT-070

Epoxy Flooring

Architectural · During Construction

Inspection covers mix times, thickness, coverage and adhesion.

4 available documentsMSCHKITP
ACT-071

Raised Access Flooring

Architectural · During Construction

Inspection covers levels, rocking, cutout support and access.

4 available documentsMSCHKITP
ACT-072

Carpet and Vinyl Flooring

Architectural · During Construction

Inspection covers pattern continuity, seam quality, adhesion and edge finish.

4 available documentsMSCHKITP
ACT-073

Timber Doors Installation

Architectural · During Construction

Inspection covers clearances, leaf operation and finish.

4 available documentsMSCHKITP
ACT-074

Steel / Fire-Rated Doors Installation

Architectural · During Construction

Inspection covers label, gaps, closer, seal continuity and frame perimeter.

4 available documentsWIRMSITP
ACT-075

Ironmongery Installation

Architectural · During Construction

Inspection covers handing, finish, operation and key schedule.

4 available documentsMSCHKITP
ACT-076

Joinery and Fixed Furniture

Architectural · During Construction

Inspection covers level, finish, support and service access.

4 available documentsMSCHKITP
ACT-077

Kitchen Cabinets Installation

Architectural · During Construction

Inspection covers alignment, worktop bearing, cutouts and operation.

4 available documentsMSCHKITP
ACT-078

Sanitary Ware Installation

Architectural · During Construction

Inspection covers mounting height, stability, leakage and flow.

4 available documentsMSCHKITP
ACT-079

Handrails and Balustrades

Architectural · During Construction

Inspection covers height, gaps, alignment and specified load tests.

4 available documentsMSCHKITP
ACT-080

Expansion Joints and Fire-Stopping

Architectural · During Construction

Inspection covers tested assembly, depth, gap, lot and concealment photos.

4 available documentsMSCHKITP
ACT-081

Signage and Wayfinding

Architectural · During Construction

Inspection covers location, legibility, symbols and fixing.

4 available documentsMSCHKITP
Façade & Building EnvelopeActivities: 10
ACT-082

Curtain Wall System Installation

Architectural · During Construction

Inspection covers bracket settings, movement, drainage and water test.

4 available documentsMSCHKITP
ACT-083

Unitised Curtain Wall Installation

Architectural · During Construction

Inspection covers panel IDs, gasket engagement, survey and test evidence.

4 available documentsMSCHKITP
ACT-084

Aluminium Windows and Doors

Architectural · During Construction

Inspection covers anchorage, plumb, weeps and weather seals.

4 available documentsMSCHKITP
ACT-085

Glazing Works

Architectural · During Construction

Inspection covers unit locations, markings, edge condition and installation checks.

4 available documentsMSCHKITP
ACT-086

Aluminium Composite Panel (ACP) Cladding

Architectural · During Construction

Inspection covers identification, anchors, fire barriers and joint alignment.

4 available documentsMSCHKITP
ACT-087

Stone Cladding (Dry Fix)

Architectural · During Construction

Inspection covers stone batch, anchor tests, restraint and final survey.

4 available documentsMSCHKITP
ACT-088

GRC / GRP Panels Installation

Architectural · During Construction

Inspection covers panel condition, connection and seam evidence.

4 available documentsMSCHKITP
ACT-089

External Wall Insulation

Architectural · During Construction

Inspection covers thickness, fixings, gaps and concealment photos.

4 available documentsMSCHKITP
ACT-090

Façade Sealants and Water Testing

Architectural · During Construction

Inspection covers joint geometry, compatibility, leakage and retest.

5 available documentsTESTMSCHK
ACT-091

Building Maintenance Unit (BMU) Installation

Architectural · During Construction

Inspection covers track or anchors, machine IDs, load test and rescue plan.

4 available documentsMSCHKITP
HVAC (Mechanical)Activities: 16
ACT-092

Ductwork Fabrication and Installation

HVAC · During Construction

Inspection covers duct sizes, joints, clearances and leakage release.

4 available documentsMSCHKITP
ACT-093

Duct Insulation

HVAC · During Construction

Inspection covers thickness, jacket continuity and access.

4 available documentsMSCHKITP
ACT-094

Duct Leakage Testing

HVAC · During Construction

Inspection covers duct class, area, calculated leakage and retest.

5 available documentsTESTMSCHK
ACT-095

Chilled Water Piping Installation

HVAC · During Construction

Inspection covers joint traceability, slopes, supports and pressure release.

4 available documentsMSCHKITP
ACT-096

Chilled Water Pipe Insulation

HVAC · During Construction

Inspection covers thickness, seams, vapour continuity and thermal breaks.

4 available documentsMSCHKITP
ACT-097

Hydrostatic Pressure Testing of Piping

HVAC · During Construction

Inspection covers approved pressure and duration, gauge IDs, readings and leakage.

4 available documentsMSCHKITP
ACT-098

Chillers Installation

HVAC · During Construction

Inspection covers tag, mounts, alignment and commissioning results.

4 available documentsMSCHKITP
ACT-099

Cooling Towers Installation

HVAC · During Construction

Inspection covers basin leakage, alignment, fan and treatment handover.

4 available documentsMSCHKITP
ACT-100

AHU / FAHU Installation

HVAC · During Construction

Inspection covers nameplate, alignment, filters, drain fall and start-up evidence.

5 available documentsMIRMSCHK
ACT-101

FCU Installation

HVAC · During Construction

Inspection covers unit tag, filter access, drain flow and controls.

4 available documentsMSCHKITP
ACT-102

Pumps Installation (HVAC)

HVAC · During Construction

Inspection covers alignment, vibration, rotation and duty readings.

4 available documentsMSCHKITP
ACT-103

Ventilation and Exhaust Fans

HVAC · During Construction

Inspection covers airflow direction, rotation, guards and performance.

4 available documentsMSCHKITP
ACT-104

Grilles, Diffusers and Dampers

HVAC · During Construction

Inspection covers tags, actuator operation, airflow settings and access.

4 available documentsMSCHKITP
ACT-105

Kitchen Exhaust System

HVAC · During Construction

Inspection covers grease-tight joints, cleanout access, fire protection and fan duty.

4 available documentsMSCHKITP
ACT-106

Flushing and Chemical Cleaning of Pipes

HVAC · During Construction

Inspection covers chemical batch, circuit results, approved limits and effluent disposition.

4 available documentsMSCHKITP
ACT-107

Testing, Adjusting and Balancing (TAB)

HVAC · During Construction

Inspection covers design versus measured readings, settings, calibration and deviations.

5 available documentsTESTMSCHK
Plumbing & DrainageActivities: 11
ACT-108

Water Supply Piping (PPR / Copper / GI)

Plumbing · During Construction

Inspection covers material and joint logs, pressure test and disinfection release.

4 available documentsMSCHKITP
ACT-109

Drainage and Soil Piping (uPVC / HDPE / Cast Iron)

Plumbing · During Construction

Inspection covers invert levels, access and flow or water test.

4 available documentsMSCHKITP
ACT-110

Storm Water Drainage

Plumbing · During Construction

Inspection covers outlet ID, endpoint, ponding and leakage.

5 available documentsTESTMSCHK
ACT-111

Underground Drainage and Manholes

Plumbing · During Construction

Inspection covers level survey, cover class, CCTV or testing and backfill clearance.

4 available documentsMSCHKITP
ACT-112

Water Pumps and Booster Sets

Plumbing · During Construction

Inspection covers approved settings, staging, duty and leaks.

4 available documentsMSCHKITP
ACT-113

Water Tanks (GRP / Steel) Installation

Plumbing · During Construction

Inspection covers panel or weld checks, seals, retention and water approvals.

4 available documentsMSCHKITP
ACT-114

Water Heaters Installation

Plumbing · During Construction

Inspection covers tag, relief path, leakage and approved settings.

4 available documentsMSCHKITP
ACT-115

Grease Traps and Interceptors

Plumbing · During Construction

Inspection covers flow direction, cover rating, vents and leakage.

4 available documentsMSCHKITP
ACT-116

Pressure Testing of Water Piping

Plumbing · During Construction

Inspection covers medium, approved pressure and duration, readings and retest.

4 available documentsMSCHKITP
ACT-117

Drainage Water Test / Flow Test

Plumbing · During Construction

Inspection covers water head or flow, leakage, drain time and retest.

4 available documentsMSCHKITP
ACT-118

Disinfection and Flushing of Water System

Plumbing · During Construction

Inspection covers treatment record, sample ID, analytical results and service release.

4 available documentsMSCHKITP
Fire Protection & Life SafetyActivities: 9
ACT-119

Sprinkler System Installation

Firefighting · During Construction

Inspection covers head types and positions, support and pressure or flow evidence.

4 available documentsMSCHKITP
ACT-120

Fire Pumps Installation

Firefighting · During Construction

Inspection covers duty results, controller sequence and certificates.

4 available documentsMSCHKITP
ACT-121

Fire Hydrant and Hose Reel System

Firefighting · During Construction

Inspection covers signage, pressure and discharge readings, tag and accessories.

4 available documentsMSCHKITP
ACT-122

Wet / Dry Riser System

Firefighting · During Construction

Inspection covers floor labels, valve orientation and pressure test.

4 available documentsMSCHKITP
ACT-123

FM200 / Clean Agent System

Firefighting · During Construction

Inspection covers cylinder IDs, enclosure integrity, abort and alarms; no unauthorised discharge.

4 available documentsMSCHKITP
ACT-124

Fire Alarm System Installation

Firefighting · During Construction

Inspection covers device addresses, loop checks, annunciation and event records.

4 available documentsMSCHKITP
ACT-125

Smoke Management / Pressurisation System

Firefighting · During Construction

Inspection covers fan and damper states, differential pressure and witness evidence.

4 available documentsMSCHKITP
ACT-126

Fire Extinguishers Installation

Firefighting · During Construction

Inspection covers serial, type, inspection date and mounting height.

4 available documentsMSCHKITP
ACT-127

Fire Protection System Testing and Commissioning

Firefighting · During Construction

Inspection covers waterflow, alarm response, pressure readings and reinstatement.

4 available documentsMSCHKITP
ElectricalActivities: 17
ACT-128

Cable Trays and Trunking Installation

Electrical · During Construction

Inspection covers spans, clearances, bond continuity and fire compartments.

4 available documentsMSCHKITP
ACT-129

Conduit Installation (Concealed / Exposed)

Electrical · During Construction

Inspection covers routes, box levels, bends and conduit fill.

4 available documentsMSCHKITP
ACT-130

LV Cable Pulling and Termination

Electrical · During Construction

Inspection covers cable IDs, torque, insulation test and phase marking.

4 available documentsMSCHKITP
ACT-131

MV Cable Installation and Testing

Electrical · During Construction

Inspection covers drum lengths, pulling log and pre-energisation certificates.

4 available documentsMSCHKITP
ACT-132

Busduct Installation

Electrical · During Construction

Inspection covers section IDs, torque, clearance, continuity and insulation.

4 available documentsMSCHKITP
ACT-133

Transformers Installation

Electrical · During Construction

Inspection covers nameplate, earthing, protection and pre-service certificates.

4 available documentsMSCHKITP
ACT-134

MV / LV Switchgear and Panels Installation

Electrical · During Construction

Inspection covers tags, interlocks, torque, earthing and tests; not energisation authority.

4 available documentsWIRMSITP
ACT-135

Distribution Boards Installation

Electrical · During Construction

Inspection covers labels, phase balance, protection and circuit tests.

4 available documentsMSCHKITP
ACT-136

Diesel Generator Installation

Electrical · During Construction

Inspection covers transfer sequence, leak checks, load performance and noise.

4 available documentsMSCHKITP
ACT-137

UPS and Batteries Installation

Electrical · During Construction

Inspection covers battery lot, polarity verification, autonomy and alerts.

4 available documentsMSCHKITP
ACT-138

Lighting Fixtures Installation

Electrical · During Construction

Inspection covers circuit IDs, switching and light readings where required.

4 available documentsMSCHKITP
ACT-139

Wiring Devices (Sockets and Switches)

Electrical · During Construction

Inspection covers polarity, protection, labels and accessibility.

4 available documentsMSCHKITP
ACT-140

Earthing and Bonding System

Electrical · During Construction

Inspection covers electrode locations, continuity and resistance certificates.

4 available documentsMSCHKITP
ACT-141

Lightning Protection System

Electrical · During Construction

Inspection covers roof layout, bonded items and resistance results.

4 available documentsMSCHKITP
ACT-142

Emergency Lighting System

Electrical · During Construction

Inspection covers locations, duration, illumination and escape coverage.

4 available documentsMSCHKITP
ACT-143

Insulation Resistance (Megger) Testing

Electrical · During Construction

Inspection covers approved test voltage, conductor pairings and readings.

4 available documentsMSCHKITP
ACT-144

Electrical Testing and Commissioning

Electrical · During Construction

Inspection covers circuit and protection tests, interlocks and defects.

4 available documentsMSCHKITP
ELV & BMSActivities: 8
Vertical TransportationActivities: 4
External Works & InfrastructureActivities: 8
Testing, Commissioning & HandoverActivities: 6